Inverter Scroll Chiller
Your Premier Inverter Scroll Chiller Manufacturer and Supplier

KEY COMPONENTS OF INVERTER SCROLL CHILLERS
- Inverter Scroll Compressor: Variable speed control for energy savings
- Evaporator: SS Tank Coil / Shell & Tube / PHE (as per model)
- Condenser: Air Cooled (Copper-Aluminum Coil with axial fans) or Water Cooled (Shell & Tube)
- Expansion Valve: Thermostatic / Electronic / Capillary (model-specific)
- Water Pump: SS304 centrifugal with high head
- Fans (Air Cooled only): EC / Inverter axial blowers
- Controller: Digital with Modbus / BMS compatibility
- Refrigerants: R22 / R407C / R134a / R404A / R410A
Design & Rating Conditions:
- Chilled Water Inlet/Outlet: 12℃ / 7℃
- Ambient Air Inlet/Outlet (Air Cooled): 33℃ / 38℃
- Condenser Water Inlet/Outlet (Water Cooled): 30℃ / 35℃ (standard for water cooled)
APPLICATIONS OF INVERTER CHILLERS
- Plastic Injection Molding
- Beverage and Dairy Process Cooling
- Pharmaceutical Clean Rooms
- HVAC Comfort Cooling
- Cold Storage
- Laser Machines / CNC Machines
- Fermentation / Food & Brewery
- Textile Dyeing and Finishing
- Battery and EV Testing Stations
Working Principle of Inverter Scroll Chiller
Compressor (Inverter Scroll): Adjusts its speed to match the cooling load.
- Refrigerant Compression: Low-pressure vapor is compressed to high pressure.
- Heat Rejection: Air-cooled via fans or water-cooled via condenser.
- Expansion Valve: Reduces refrigerant pressure before evaporator.
- Evaporator: Absorbs heat from chilled water/glycol loop.
- Water Pump: Circulates chilled fluid to application load.
- Inverter: Continuously adjusts motor/compressor speed for energy efficiency.
WATER PIPING GUIDELINES
- Chilled Water: Insulated PPR / SS / HDPE piping
- Inlet/Outlet Pipes: Refer technical table (3/4″ to 6″)
- Avoid air entrapment: Include air release valves
- Isolate with butterfly or ball valves for maintenance
- Always ensure proper NPSH for pumps
SOUND PRESSURE & POWER LEVELS (Typical Range)
- TR Sound Pressure (dBA @ 1m) Input Power (kW)
- 1–10 TR 60–66 dBA 1.1 – 6.0
- 15–50 TR 68–74 dBA 7.5 – 35
- 60–200 TR 74–78 dBA 36 – 150
SAFETY DEVICES (Standard on All Models)
-
- Compressor Internal Protection
- High/Low Pressure Cut-out
- Overcurrent & Overload Protection
- Flow Switch Protection
- Low Coolant Level Protection
- Freeze Protection (for glycol systems)
- Anti-phase / Phase Loss Protection
- Exhaust Overheat Protection
- Water Pump Overload
- Temperature Sensor Fail-Safe
- High Discharge Temperature Protection
WHY FIDEM IS YOUR TRUSTED INVERTER CHILLER PARTNER
- 15+ Years Manufacturing Experience
- Full Range: 1 TR to 200 TR (Air & Water Cooled)
- Energy-efficient Inverter Technology
- Fully Customizable Solutions
- Strong After-Sales Service & Spares
- ISO, CE, IEC, RoHS Certified
- Exported to Africa, Gulf, South Asia
Troubleshooting Tips
Issue Possible Cause Solution
Low Cooling Clogged filters, low refrigerant, dirty condenser Clean filters, top-up gas, service condenser Unit Trips Phase error, overcurrent Check power input, reset controller High Pressure Poor air flow / blocked water Clean condenser, check pump operation
Low Flow Alarm Air lock, pump fault Bleed air, check pump Unusual Noise Loose compressor bolts / faulty fan Inspect mounting / replace fan motor
Inverter Error Communication / parameter fault Check HMI, reset inverter, verify settings
💬